.. currentmodule:: sardana.macroserver.macros.scan

.. _sardana-users-scan:

=====
Scans
=====

Perhaps the most used type of macro is the scan macros. In general terms, we
call *scan* to a macro that moves one or more :ref:`motors <sardana-motor-api>`
and acquires data along the path of the motor(s).

.. note:: Sardana provides a :ref:`Scan Framework <sardana-macros-scanframework>`
   for developing scan macros so that the scan macros behave in a consistent way.
   Unless otherwise specified, the following discussion applies to scan macros
   based on such framework.

The various scan macros mostly differ in how many motors are moved and the
definition of their paths.

Typically, the selection of which data is going to be acquired depends on the
active *measurement group* and is *not* fixed by the macro itself (although
there is no limitation in this sense).

Depending on whether the motors are stopped before acquiring the data or not, we
can classify the scan macros in *step* scans or *continuous* scans,
respectively.


.. figure:: /_static/trend_ascanVSascanc.png 
   :width: 100%
   :figwidth: 80%
   :align: center
   
   Trend plot showing a step scan (:class:`ascan` *m_cp1_1 0 1000 8 .5*)
   followed by a continuous scan (:class:`ascanc` *m_cp1_1 0 1000 .5*).
   The line corresponds to the motor position and the blue shaded areas
   correspond to the intervals in which the data acquisition took place.  



Step scans
----------

In a step scan, the motors are moved to given points, and once they reach each
point they stop. Then, one or more channels are acquired for a certain amount
of time, and only when the data acquisition is finished, the motors proceed to
the next point.

In this way, the position associated to a data readout is well known and does
not change during the acquisition time.

Some examples of step scan macros are:
:class:`ascan`,
:class:`a2scan`, ...
:class:`dscan`,
:class:`d2scan`, ...
:class:`mesh`. 

Continuous scans
----------------

In a continuous scan, the motors are not stopped for acquisition, which
therefore takes place while the motors are moving. The most common reason for
using this type of scan is optimizing the acquisition time by not having to
wait for motors to accelerate and decelerate between acquisitions.

.. note:: The synchronization of movement and acquisition can be done via
   hardware or via software. Currently Sardana only provides an interface for
   software-synchronized continuous scans. An API abstracting the specificities
   of hardware-synchronized systems is being implemented too but it is not yet
   available for production.

The (software-synchronized) continuous scans introduce some constraints and
issues that should be considered.

#. If a continuous scan involves moving more than one motor simultaneously
   (as it is done, e.g. in :class:`~sardana.macroserver.macros.scan.a2scan`),
   then the movements of the motors should be synchronized so that they all
   start their path at the same time and finish it at the same time. 
#. If motors do not maintain a constant velocity along the path of their
   movement, the trajectories followed when using more than one motor may not
   be linear.
#. While in step scans it is possible to scan two pseudo-motors that access
   the same physical motors (e.g. the *gap* and *offset* of a slit, being both
   pseudo-motors accessing the same physical motors attached to each blade of
   the slit), in a continuous scan the motions cannot be decoupled in a
   synchronized way.
#. In order to optimize the acquisition time, Sardana attempts to perform as
   many acquisitions as allowed during the scan time. Due to the uncertainty in
   the delay times involved, it is not possible to know beforehand how many
   acquisitions will be completed. In other words, the number of acquired
   points along a continuous scan is not fixed (but it is guaranteed to be as
   large as possible).
#. Backslash correction is incompatible with continuous scans, so you should
   keep in mind that continuous scans should only be done in the backslash-free
   direction of the motor (typically, by convention the positive one for a
   physical motor).

  

In order to address the first two issues, the
:ref:`scan framework <sardana-macros-scanframework>` attempts the following:

* If the motors support changing their velocity, Sardana will adjust the
  velocities of the motors so that they all start and finish the required path
  simultaneously. For motors that specify a range of allowed velocities, this
  range will be used (for motors that do not specify a maximum allowed
  velocity, the current "top velocity" will be assumed to be the maximum)
* For motors that can maintain a constant velocity after an acceleration phase
  (this is the case for most physical motors), Sardana will transparently
  extend the user-given path both at the beginning and the end in order to
  allow for the motors to move at constant velocity along all the user defined
  path (i.e., the motors are allowed time and room to accelerate before
  reaching the start of the path and to decelerate after the end of the nominal
  path selected by the user)
   
These two actions can be seen in the following plot of the positions of the two
motors involved in a :class:`~sardana.macroserver.macros.scan.a2scanc`.

.. figure:: /_static/trend_a2scanc.png 
   :width: 100%
   :figwidth: 80%
   :align: center

   Trend plot showing a two-motor continuous scan 
   (:class:`a2scanc` *m_cp1_1 100 200  m_cp1_2 0 500 .1*).
   The lines correspond to the motor positions and the blue shaded areas correspond to the intervals in 
   which the data acquisition took place.  
 

Both motors are capable of same velocity and acceleration, but since the
required scan path for m_cp1_1 is shorter than that for m_cp1_2, its top
velocity has been adjusted (gentler slope for m_cp1_1) so that both motors go
through the user-requested start and stop positions simultaneously.

The same figure also shows how the paths for both motors have been automatically
(and transparently, for the user) extended to guarantee that the user defined
path is followed at constant velocity and that the data acquisition takes place
also while the motors are running at constant velocity.



Some examples of continuous scan macros are:
:class:`ascanc`,
:class:`a2scanc`, ...
:class:`dscanc`,
:class:`d2scanc`, ...
:class:`meshc`. 

.. seealso:: For more information about the implementation details of the scan
             macros in Sardana, see 
             :ref:`scan framework <sardana-macros-scanframework>`